ASTRON RS-20M-AP
LED BACKLIT VOLT AND AMP METERS
SOLID STATE ELECTRONICALLY REGULATED
FOLD BACK CURRENT LIMITING Protects Power Supply from excessive current and continuous shorted output
CROWBAR OVER VOLTAGE PROTECTION on all models except RS-4A, RS-4L, RS-5A, RS-5L
MAINTAINS REGULATION AND LOW RIPPLE at low line input Voltage
THREE CONDUCTOR POWER CORD
HEAVY DUTY HEAT SINK
CONTINUOUS DUTY: 16 Amps
ICS*: 20 Amps
POWER TERMINALS: 1/4"-20 Screw Type & Front Panel Anderson Power Poles Installed
AC POWER DRAW
- IDLE: 215mA
- FULL LOAD: 3.4A
INPUT VOLTAGE: 105-125VAC
OUTPUT VOLTAGE: 13.8VDC ±0.05 volts
OPERATING TEMP: -10 to 55°C
FUSE: GMC 5A
RIPPLE: LESS THAN 5MV PEAK TO PEAK (full load and low line)
LOAD REGULATION: 0.08% from 0 to Full Continuous Load
EFFICIENCY: 77%
FAN COOLED: No
DIMENSIONS: 5 x 9 x 10½"